Honeywell TH6110D1005/U Wall Thermostat Owners Guide

Honeywell-TH6110D1005-U-Wall-Thermostat-product

Honeywell TH6110D1005/U Wall Thermostat

Honeywell-TH6110D1005/U-Wall-Thermostat-PRODUCT

Specifications

Introduction

This thermostat provides electronic control of 24 VAC single-stage heating and cooling systems, or 750 mV heating systems.

Power Options

Changeover Options

System Settings

Fan Settings

Must be installed by a trained, experienced technician

CAUTION
ELECTRICAL HAZARD
Can cause electrical shock or equipment damage. Disconnect power before beginning installation.

MERCURY NOTICE
If this product is replacing a control that contains mercury in a sealed tube, do not place the old control in the trash. Contact your local waste management authority for instructions regarding recycling and proper disposal

Installation tips

Install the thermostat about 5 feet (1.5m) above the floor in an area with good air circulation at an average temperature.

Honeywell-TH6110D1005/U-Wall-Thermostat-Fig-1

Do not install in locations where the thermostat can be affected by

Pre-installation checklist

Check to make sure your package includes the following items

Honeywell-TH6110D1005/U-Wall-Thermostat-Fig-2

Required tools & supplies

Wallplate installation

Insert a finger into wire hole and pull to remove the wallplate from the thermostat.

Honeywell-TH6110D1005/U-Wall-Thermostat-Fig-3

Remove the wallplate from the thermostat as shown on the left, then follow the directions below for mounting.

  1. Insert a quick reference card in a slot in back of the thermostat
  2. Pull wires through the wire hole.
  3. Position the wallplate on wall, level and mark hole positions with a pencil.
  4. Drill holes at marked positions as shown below, then tap in supplied wall anchors.
  5. Place wallplate over anchors, insert and tighten mounting screws

Honeywell-TH6110D1005/U-Wall-Thermostat-Fig-4

Wiring

CAUTION
ELECTRICAL HAZARD. Can cause electrical shock or equipment damage. Disconnect power before wiring.

Honeywell-TH6110D1005/U-Wall-Thermostat-Fig-5

NOTES

R & Rc terminals
In a single-transformer system, leave a metal jumper in place between R & Rc. Remove the metal jumper if a two-transformer system.

C terminal
The C (common wire) terminal is optional when the thermostat is powered by batteries.

W (O/B) terminal
If the thermostat is configured for a heat pump in the Installer Setup, configure the changeover valve for cool (“O” factory setting) or heat (“B”).

Wire specifications
Use 18- to 22-gauge thermostat wire. A shielded cable is not required.

  1. Loosen screw terminals, insert wires into the terminal block, then re-tighten the screws.
  2. Push excess wire back into the wall opening. Keep wires in the shaded area as shown on left.
  3. Plug the wall opening with nonflammable insulation to prevent drafts from affecting thermostat operation.

Terminal Designations

Wiring diagrams

  1. Power supply. Provide disconnect means and overload protection as required.
  2. Factory-installed jumper. Remove for 2-transformer systems only.
  3. Optional 24VAC common connection.
  4. In Installer Setup, set the system type to Heat Only.
  5. In Installer Setup, set the system type to Heat Pump & changeover the valve to 0 or B.

Typical 1H/1C system: 1 transformer Typical 1H/1C system: 2 transformers

Honeywell-TH6110D1005/U-Wall-Thermostat-Fig-6

Typical 1H/1C heat pump system Typical heat-only system

Honeywell-TH6110D1005/U-Wall-Thermostat-Fig-7

  1. Power supply. Provide disconnect means and overload protection as required.
  2. Factory-installed jumper. Remove for 2-transformer systems only.
  3. Optional 24VAC common connection.
  4. In Installer Setup, set the system type to Heat Only.
  5. In Installer Setup, set the system type to Heat Pump & changeover valve to 0 or B.

Typical heat-only system with fan Heat-only system (Series 20)

Honeywell-TH6110D1005/U-Wall-Thermostat-Fig-8

Typical cool-only system Heat-only system (normally open zone valve)

Honeywell-TH6110D1005/U-Wall-Thermostat-Fig-9

Power options & mounting

Honeywell-TH6110D1005/U-Wall-Thermostat-Fig-10

AC Power

The thermostat can be powered by 24 VAC power, or by batteries. To wire the thermostat for AC power, connect the common side of the cooling transformer to the “C” terminal as shown at left.

Important
Remove R/Rc jumper for 2-transformer systems only. (See wiring diagram on page 5.)

Battery Power

The thermostat can be powered by batteries alone or, if used with AC power, can provide backup power. During power interruptions, the batteries will save time/day settings and power the display.
After installation, batteries can be changed without removing the thermostat from the wall (see page 11).

To Mount Thermostat
Align the 4 tabs on the wallplate with corresponding slots on the back of the thermostat, then push gently until the thermostat snaps in place.

Honeywell-TH6110D1005/U-Wall-Thermostat-Fig-11

Installer setup

Follow the procedure below to configure the thermostat to match the installed heating/cooling system, and customize feature operation as desired.

Honeywell-TH6110D1005/U-Wall-Thermostat-Fig-12

To begin, press and hold the FAN buttons until the display changes

Honeywell-TH6110D1005/U-Wall-Thermostat-Fig-13

Installer system test

Follow the procedure below to test the heating, cooling, and fan.

Honeywell-TH6110D1005/U-Wall-Thermostat-Fig-14

To begin, press and hold the buttons until the display changes.

Honeywell-TH6110D1005/U-Wall-Thermostat-Fig-15

CAUTION
EQUIPMENT DAMAGE HAZARD
Compressor protection (minimum off time) is bypassed during testing. To prevent equipment damage, avoid cycling the compressor quickly.

Auto Changeover (Setup Function 12)

Honeywell-TH6110D1005/U-Wall-Thermostat-Fig-16

Adaptive Intelligent Recovery™ (Setup Function 13)

For example
Set the Wake time to 6 am, and the temperature to 70°.The heat will come on before 6 am, so the temperature is 70° by the time you wake at 6.

Built-in compressor protection (Setup Function 15)

Honeywell-TH6110D1005/U-Wall-Thermostat-Fig-17A quick reference to controls

Honeywell-TH6110D1005/U-Wall-Thermostat-Fig-18

Quick reference to display screen

Honeywell-TH6110D1005/U-Wall-Thermostat-Fig-18

Battery replacement

Honeywell-TH6110D1005/U-Wall-Thermostat-Fig-20

In case of difficulty

If you have difficulty with your thermostat, please try the suggestions below. Most problems can be corrected quickly and easily.

Display is blank

Temperature settings do not change

Make sure heating and cooling temperatures are set to acceptable ranges:

The heating system does not respond (“Heat On” appears on screen)

The cooling system does not respond(“Cool On” appears on screen)

The fan does not turn on in a call for heat

Heat pump issues cool air in heat mode, or warm air in cool mode

Heat/cool both on at the same time, or heat does not turn off

Heating equipment is running in cool mode

Cannot change system set to “Heat”

Cannot change system set to “Cool”

“Heat On” is not displayed

“Cool On” is not

“Cool On” or “Heat On” is flashing

Accessories & replacement parts

Please contact your distributor to order replacement parts

(Use to cover marks left by old thermostats.)

REFERENCE